TM 5-3610-287-24
Table 2-3.
Organizational Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
20.
WALL OUTLET DOES NOT OPERATE (CONT)
WARNING
Turn off main power switch before performing this
task. Failure to do so may result in death or
serious injury.
Set MAIN POWER switch to OFF. Remove power cable at
Step 4.
connector. Set MAIN POWER switch to ON. Test voltage at
power cable receptacle across pins lettered K and E
(curbside) or D and H (roadside). Reading should be 110
10 Vac.
If reading is not correct, troubleshoot circuit breaker
(malfunction 14).
If reading is correct, repair expanding side power cable
21.
WARNING
HIGH VOLTAGE. When working on high voltage
components, always have an additional person
present. Keep one hand away from equipment to
reduce hazard of current flowing through vital
organs of body. Remove all jewelry from
fingers, wrists, and neck before working on
electrical components. Failure to observe this
warning may result in death or serious burns.
Step 1.
Check that wall outlet circuit breaker is ON.
Set wall outlet circuit breaker to ON.
Test voltage at wall outlet.
Reading should be 110 10
Step 2.
Vac.
Troubleshoot wall outlet (malfunction 20).