TM 5-3610-287-24
Table 2-3.
Organizational Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
25.
WALL HEATER CIRCUIT BREAKER CONTINUALLY TRIPS (CONT)
Step 4.
Cut blue and black input wires to wall heater below crimp
connector. Insulate input wire ends by wrapping with
electrical tape. Set HEATER circuit breaker to ON.
If cutting wires corrects malfunction, replace
If malfunction still exists, troubleshoot circuit
breaker (malfunction 14).
26.
PRESS DOES NOT OPERATE.
Check that press circuit breaker is on.
Step 1.
Set circuit breaker to ON.
WARNING
q Turn
off main power switch before performing
this task. Failure to do so may result in
death or serious injury.
q HIGH
VOLTAGE. When working on high voltage
components, always have an additional person
present. Keep one hand away from equipment
to reduce hazard of current flowing through
vital organs of body. Remove all jewelry
from fingers, wrists, and neck before
working on electrical components. Failure
to observe this warning may result in death
or serious burns.
Set MAIN POWER switch to OFF. Remove circuit breaker cover
Step 2.
panel. Set MAIN POWER switch to ON. Test voltage at each
circuit breaker terminal. Reading should be 110 10 Vat.
If reading is not correct, replace circuit breaker (para
If reading is correct, refer equipment to depot
maintenance for repair.