TM 5-3610-287-24
Table 2-3.
Organizational Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
18.
DOME LIGHT DOES NOT OPERATE (CONT)
Remove dome light from ceiling. Test voltage between dome
Step 3.
light wire and Section ground. Reading should be 12 Vdc.
WARNING
Turn off main power switch before performing this
task. Failure to do so may result in death or se-
rious injury.
NOTE
This step applies to dome light in expanding side
only.
Set MAIN POWER switch to OFF. Remove cover on curbside
Step 4.
expanding side cable junction box. Test voltage on wire
numbered 14 to ground. Reading should be 12 Vdc.
If reading Is 12 Vdc, refer equipment to depot
maintenance for repair of interior wiring.
If reading Is not 12 Vdc, go to next step.
Remove expanding side power cable connector. Test voltage
Step 5.
from pin F of cable receptacle to ground. Reading should
be 12 Vdc.
If reading is correct, repair expanding side power cable
2-22