TM 5-3610-287-10
Troubleshooting (Cont)
Table 3-1.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2.
NO ELECTRICAL POWER TO SECTION (CONT)
Inspect power cable for cracks, breaks, or frayed wiring.
Step 3.
If malfunction still exists , notify your supervisor.
Check that external power is being provided.
Step 4.
If malfunction still exists, notify your supervisor.
3.
RESISTANCE (BINDING) FELT WHEN EXPANDING SIDES ARE EXPANDING.
Check inclinometers to see if Section is level.
Step 1.
Step 2.
Check for exterior obstructions.
Remove exterior obstructions or move Section.
Check that sides are expanding evenly.
Step 3.
If malfunction still exists, notify your supervisor.
4.
RESISTANCE (BINDING) FELT WHEN EXPANDING SIDES ARE RETRACTING.
Check inclinometers to see if Section is level.
Step 1.
Check that removable floor sections have been taken up.
Step 2.
Check that Printing Press swinging step is locked under
Step 3.
delivery end of Printing Press.
Lock swinging step under delivery end of Printing Press.
Check that Printing Press manual inking roller handle
Step 4.
points toward feeder end of Printing Press.
Reposition manual inking roller handle.