TM 5-3610-286-20
2-51.
Shaft Assembly.
This task covers:
Repair
INITIAL SETUP
Tools
Feeler gage
4 mm hex key
6 mm combination wrench
Flat-tip screwdriver
NOTE
Repair of the shaft assembly at the organizational level is limited to adjusting
knobs and associated hardware.
Repair. (figure 2-114)
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
2-266
NOTE
Set adjustment knobs to 0. Measure gap between the bottom of knobs and top
of adjuster and record before repairing.
Remove pan-head screw (1), pointer (2), and shim plate (3).
Remove knurled locking screw (4).
Remove two adjustment knobs (5).
Remove V-ring (6).
Remove socket-head screw (7), washer (8), and compression spring (9).
Remove slotted screw (10) and washer (11).
Remove three rivets (12), indicator plate (13), and set screw (14).
Replace worn indicator plate (13), weak or broken spring (9), stripped adjustment knobs
(5), and damaged pointer (2).
Replace set screw (14), indicator plate (13), and three rivets (12).
Replace washer (11) and slotted screw (10).