TM 5-3610-286-20
2-52.
Front Lay Assembly (cont).
c. Adjust.
(1) Front lay height adjustment, (figure 2-116)
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(i)
(1)
(k)
2-270
Set front lay height adjustment screws (D/S) and (O/S) to zero.
WARNING
When working on high-voltage components, always have an additional person
present, and keep one hand away from equipment to reduce hazard of current
flowing through vital organs of body. Remove all jewelry from fingers, wrists,
and neck prior to working on electrical components. Failure to do so may
result in death or serious burns.
With main power switch ON, take printing press off safe and inch until front lays (1) are
in their lowest position over feeder table (2).
Put printing press on safe.
Insert 0.10 mm feeler gage between front lays (1) and feeder table (2) and check that it
is snug in front lay. If snug, no adjustment is needed, If not, go to step (e).
Take printing press off safe and inch until socket-head screw (3) is accessible. Loosen
screw.
Put printing press on safe and loosen socket-head screw (3).
Lift front lay (1) to highest position over feeder table (2).
Finger tighten socket-head screw (3).
Take printing press off safe and inch until front lays are again in their lowest position.
Put printing press on safe.
Insert 0.10 mm feeler gage under front lay (1) and adjust front lay down until feeler gage
can be pulled out with slight drag.
NOTE
If feeler gage cannot be inserted, go to step (o).