TM 5-3610-285-14
x.
Remove four screws and motor mounting bracket from defective drive motor. Install bracket on new drive
motor.
y.
Install new drive motor assembly in film processor, and secure with mounting bolts, flat washers, and nuts. Do
not tighten nuts.
z.
Move drive motor upward and reinstall drive chain on sprocket. Reinstall chain guard. Tighten nuts on motor
mounting bolts.
aa. Reconnect ground wire.
ab. Install rotor and retaining screw that were removed from defective drive motor.
ac. Install adapter and secure with three screws.
ad. Install generator assembly and secure with retaining screws.
ae. Reinstall generator splash guard.
af. Pull new drive motor cable through strain relief bushing at rear of control unit.
ag. Connect new drive motor wiring to terminals on control unit terminal block. Reinstall control unit cover.
Reinstall cable into retaining straps and install new wire ties to drive motor cable.
ah. Reconnect hoses to fixer recirculation pump assembly. Tighten hose clamps.
ai. Reattach recirculation pump assembly to processor frame. Secure with bracket, phenolic block, and three
screws.
aj. Reinstall developer temperature control circuit board 700. Secure bracket to frame with two screws.
ak. Reinstall fixer and developer pump splash cover.
al. Reinstall top cover and left access panel.
am. Turn on processor circuit breaker.
5-155