TM 5-3610-285-14
d.
Remove generator splash guard.
e.
Remove retaining screws and generator assembly. Set generator assembly and wiring aside.
f.
Remove three screws and adapter.
g.
While holding shaft nut with combination wrench, remove retaining screw and rotor.
h.
Remove cable from retaining straps and cut wire ties from drive motor cable.
i.
Remove control unit cover.
j.
Tag and disconnect drive motor wires from control unit terminal block.
k.
Remove entire drive motor cable through strain relief bushing at rear of control unit.
l.
Remove ground wire from drive motor, and from processor frame.
m. Remove chain guard. Loosen drive motor mounting bolts. Move drive motor upward, and remove drive chain.
5-153