Remove developer temperature control circuit board 700, with bracket, by removal of two mounting screws
from processor frame. Move circuit board and bracket aside.
o.
Remove three screws, bracket, and phenolic block from processor frame. This will release the fixer
recirculation pump assembly from the frame.
p.
Loosen three fixer recirculation pump hose clamps nearest the pump assembly housing.
q.
Disconnect hoses at the recirculation pump. Remove pump assembly and set aside.
r.
Remove drive motor mounting bolts, nuts, and flat washers.
s.
Carefully slide drive motor toward front of processor, while turning motor on its side, and rotating motor
mounting bracket upward.
t.
Remove defective drive motor and mounting bracket from film processor.
u.
Measure and record the distance from side of drive sprocket to end of drive motor shaft.
v.
Loosen setscrew and remove sprocket.
w. Install sprocket to shaft of new drive motor assembly. Adjust sprocket to distance recorded in step u. Tighten
setscrew.