TM 5-3610-285-14
5-16.12 Replace Control Unit Fuse.
MOS: 83FJ6, Reproduction Equipment Repairer
TOOLS:
Tool Kit, Light Machine Repair
Cross Tip Screwdriver
Flat Tip Screwdriver
Fuse Puller
SUPPLIES: Fuse, 5 amp
WARNING
Death or serious injury may occur from electrical shock unless processor circuit breaker is turned off
before servicing.
a.
Turn off processor circuit breaker.
b.
Remove left access panel.
c.
Remove retaining screws and remove control unit cover.
d.
Remove control unit fuse.
e.
Install new control unit fuse.
f.
Reinstall control unit cover and retaining screws.
g.
Reinstall left access panel.
h.
Turn on processor circuit breaker.
5-148