TM 5-3610-253-14
5-40.17 Check
Clearance Between Knife
and Clamp.
MOS: 83FJ6, Reproduction Equipment Repairer
PERSONNEL: Two persons are required to perform this procedure.
Flat Tip Screwdriver
TOOLS:
Knife Reset Handles
Knife Carrying Handles
Metric Feeler Gage (0.3 mm)
Turn off power.
a.
(1)
Turn Star-Delta switch to Y position, then to O position.
(2)
Turn main power switch to O position.
b. Remove main motor V-belt cover.
c.
WARNING
Keep hands and feet clear of main motor and hydraulic pump V-belt.
Death or serious injury may occur from failure to do so.
d. Turn on power.
(1) Turn main power switch to I position.
(2) Turn Star-Delta switch to Y position. After main motor has reached
full speed, turn switch to
position.
(3) Press control power on switch.
e.
Move the backgauge forward or backward as required until backgauge
position is displayed on the measurement display.
f. Place a pile of paper under the clamp.
5-539