TM 5-3610-253-14
Replace Knife.
MOS: 83FJ6, Reproduction Equipment Repairer
TOOLS: T-Handle Key (8 mm Hex Head key)
Knife Carrying Handles (2)
Knife Setting Gage
36/41 mm Double Open End Wrench (2)
SUPPLIES: Knife
Turn on circuit breaker.
a.
b. Using operator key, unlock safety lock.
c.
Turn on power.
(1) Turn main power switch to I position.
(2) Press control power on switch.
WARNING
Be sure personnel and foreign materials are clear of the cutting and
clamping area before pressing the cutting buttons. Death or serious
injury may occur.
d. Step on clamp foot pedal and lower clamp to table and hold.
Change 1
5-165