TB 1-4920-443-35
AEDATS II T700 Alignment Worksheet
(Refer to
page 58 step 51) 9530A DATRONICS
(a) Zero indicator and install torque arm and pan, push down and release. Lift up on
arm and
release. Adjust to zero
1 Note old r-cal value._______ for Ref. Only ( check old R Cal)
(b) Install 100 lbs of weight (Torque= 200 ft-lb)
1 Adjust span coarse and fine controls until results are obtained
(c) Add 100 lbs of weight for a total of 200 lbs and verify the indicator reads 400 ft-lb (+/-2 ft-lb)
(d) Add 100 lbs of weight for a total of 300 lbs and verify the Indicator reads 600 ft lbs (+/-2 ft-lb)
Weights
Torque
Datronics indicator
Torque
AEDATS 2
Ft-lb
+/-2 ft-lb
in-lb
(Qdyno)
+/- 10 in-lb
0
0
____________
0
____________
100 Lbs
200
____________
2400
____________
200 Lbs
400
____________
4800
____________
300 Lbs
600
____________
7200
____________
(e) Torque R-cal___________ holding - R Cal down Datronics Remove torque arm and pan
(f) Re-adjust balance and span pots to read zero and the new r-cal respectively
(g) Adjust AEDATS to Datronics Zero
(18)RPM
(a) Ensure indicator is in rpm mode. Adjust balance and span controls for a zero indication +/- 1 Hz
(b) Input a signal of 1393.3 Hz on pins 8 and 9 of the E-1 cable and adjust balance and span controls
for an indication of 20,900 rpm +/- 10 rpm
1 Zero_________, Span__________ Rpm R-cal___________
(19)SHP
(a) Ensure indicator is in
Shp mode. Set zero. Push Shp cal and - cal (torque) button and verify the
indication is the product of the values of the R-cals noted above, divided by 5252
1 Torque R-cal _________x Rpm R-ca l___________/5252 = Shp_________
(b) If the displayed value is not correct adjust the span controls to obtain the value attained
mathematically (displayed value)____________
117