TB 1-4920-443-35
AEDATS II T700 Alignment Worksheet
NOTE
Input the following frequencies into connector MT206 pins A (+) and B (-). Center Flowmeter.
Note: Cell constant high K Factor (#5)
Oscillator Hz
Calculating Counter
AEDATS 2
Calculating Counter
AEDATS 2
Hz +/- 1
Sheet Hz
PPH+/- .5 %
(WF1)
(WF1)
Hz +/- 1
PPH +/- .35 %
240Hz
____________
____________ ____________
____________
____________
480Hz
____________
____________ ____________
____________
____________
720Hz
____________
____________ ____________
____________
____________
960Hz
____________
____________ ____________
____________
____________
1200Hz
____________
____________ ____________
____________
____________
(Note: frequency x C = PPH) (CH 4C= 3600 x 8.337 x SG /K factor)
(14)Speed Measurement System
(Refer to page 51
step 47
) CEC 2700 or
Function Generator
(a) Power turbine speed (NP) (N2) speed indicator (T700/T701/T701C)
1 Set calculating counter controls as follows: (Channel 2)
2 DEC
4
3 C
07502
4 10n periods
0
5 Auto
depressed
6 x10
depressed
7 Sample rate to (fast)
1
8 Test
released
(b) Power turbine speed (NP) (N2) speed indicator (T401/T401C)
1 Set calculating counter controls as follows: (Channel 2)
2 DEC
4
3 C
07179
4 10n periods
0
5 Auto
depressed
6 x10
depressed
7 Sample rate to (fast)
1
8 Test
released
(c) Set the CEC 2700 oscillator controls as
follows: (NP)
1 Level 500mV to 1.5 V Rms, (voltage is needed to drive amp)
(d) Input the following frequencies into connector E1 pins 8 and 9.
Oscillator
Calculating
AEDATS 2
Gauge Analog
Gauge Digital
Frequency
counter
+/- 5%
+/- .3%
(RPM 4)
+/- .3%
+/- 1hz
133hz (10%)
____________
____________
____________
____________
533hz (40%)
____________
____________
____________
____________
800hz (60%)
____________
____________
____________
____________
1200hz
____________
____________
____________
____________
(90%)
1333hz
____________
____________
____________
____________
(100%)
115