TB 1-4920-443-35
AEDATS II T700 Alignment Worksheet
(d) Channel 4 Connector P91 Pins N (+) G (-)
Output(mAvg)
(Vert. Scale)
(Limits)
AEDATS 2
Meter
(V4)
____________
____________
Shorted
100hz
116.5
____________
.9-1.1
____________
100hz
233.0
____________
1.9-2.1
____________
100hz
350.0
____________
2.9-3.1
____________
100hz
466.0
____________
3.9-4.1
____________
100hz
583.0
____________
4.9-5.1
____________
(e) Channel 5 Connector P91 Pins B (+) M (-)
Output(mAvg)
(Vert. Scale)
(Limits)
AEDATS 2
Meter
(V5)
____________
____________
Shorted
100hz
116.5
____________
.9-1.1
____________
100hz
233.0
____________
1.9-2.1
____________
100hz
350.0
____________
2.9-3.1
____________
100hz
466.0
____________
3.9-4.1
____________
100hz
583.0
____________
4.9-5.1
____________
(12)Vibration system (vibration Test # 2)
NOTE
Ensure that the 2700 Calibration box internal switch is in the on position. The Calibration
lab may leave the switch in the off position due to calibration procedure
(a) Use J1 with red cable (CEC-619566-120) and T700 engine vibration cable to drive the charge
amps.
(b) Connect test box CEC 2700 (J1) to the inputs of the charge amps cables.
(c) Set channels 1, 2, and 3 meters as follows:
1 Filter switch to CAL
2 Range switch to 150
3 Xducer switch to ACC
4 Mode switch to VEL
5 Output switch to AVG
6 Variable filter Out
7 Adjust Cal pot for a reading of 50 on Ch2. and 10 on Ch. 1 and 3.
8 Set filter sw to SENS
9 Adjust SENS pot for a reading of 150/75 on the digital display of channels 1, 2, and 3.
NOTE
(75 only applies to sites with Endevco system installed)
Set XDUCER switch to VEL
10
Set OUTPUT sw to RMS.
11
Range 5
12
Filter OUT
13
Variable switch to position 1 (T700)
14
113