TB 1-4920-443-35
AEDATS II T700 Alignment Worksheet
(15)Over Speed channels (NP)
(a) Over speed power section #1.
(b) Set the CEC 2700 oscillator controls as
follows: (NP)
1 Level 500mV to 1.5 V, (voltage is needed to drive amp)
(c) Input the following frequencies into connector E1 pins 8 and 9. Thumbwheel setting 1333
Speed
Limit control indicator
Hz/%
+/- .3hz
133hz (10%)
____________
533hz (40%)
____________
800hz (60%)
____________
1200hz (90%)
____________
1333hz (100%)
____________
NOTE
Over speed power section #2 is not connected
(d) Set frequency at
90% and 100% of
thumbwheel setting to
check alarms
1 90% alarm 1200 Hz______100% alarm 1333 Hz _______audible alarm Y/N_____
(16)Power turbine speed (NG) speed indicator
(a) Set calculating counter controls as follows: (Channel 1)
1 DEC
4
2 C
04682
3 10n
0
4 Auto
depressed
5 x10
released
6 Sample rate (fast)
1
7 Test
released
1 Level 500mV to 1.5 V, (voltage is needed to drive amp)
(c) Input the following frequencies into connector E3 pins 20 and 21.
Oscillator
Calculating
AEDATS 2
Gauge Analog
Gauge Digital
counter
+/- .3%
+/- .3%
(RPM 2)
+/- .3%
+/- 1hz
214hz (10%)
____________
____________
____________
____________
854hz (40%)
____________
____________
____________
____________
1282hz
____________
____________
____________
____________
(60%)
1709hz
____________
____________
____________
____________
(90%)
2136hz
____________
____________
____________
____________
(100%)
116