TB 1-4920-443-35
(2) Enter Data from Calibration sheet (Compatible with Windows 98 or older)
(1) Open shortcut to Linear Link.
(2) EDIT: Go to link setup. 0-10 V Out, RF Input and Top flow and Top Freq. From Cal Sheet.
(3) EDIT: Header Fields enter Data from Calibration sheet. (Enter)
(4) VIEW: Mechanical Data(Enter)
(5) EDIT: Data fields enter 20 calibration points. (Enter)
(6) CONNECT INTERFACE CABLE TO LAPTOP AND LINEARIZER
(8) VIEW: Open K Factor Plot (Enter)
(9) SHOULD SAY table generation successful. (OK)
(10)PROGRAM: Program Link (OK)
(11)Will download Data loaded from Calibration sheet
(12)Enter low reading on voltage out ___________ (Enter)
(13)Enter High reading on voltage out ___________ (Enter)
(14)Verify Analog reading on voltage out ___________ (Enter)
(15)Should Say Sending Table
(16)Should read Calibration performed successful.
c. Enter Specific Gravity in AEDATS under initialization (fuel correction factor) for PPH on
Calibration sheet.
(1) Enter the fuel flow correction factor or linearizer conversion factor into calculating counter CH 4
C switches. Enter this value in the five thumbwheel switches marked "C".
Provide corrections and place formula 78 X 8.337 X SG / 2000 in correct context.
K- Factor = Hz. x Time base / Flow rate
(Note: enter c=01000 into counter to read frequency)
PPH= GPM x 500 x SG.
or GPM= ___PPH_____
500 x S. G.
PPH= Pulses per second (hz). X 3600 x S. G. x 8.347 / pulses per gallon ( K Factor)
(2) At the Fuel Trailer, open the cover of the Flow Linearizer (P/N LN 5-C-V1B6) mounted next to the J-
box. Connect the CEC 2700 oscillator from J2 connector A(+) and B(-) to TB 201 terminals 1+ and 2-.
NOTE
Note: The T63 Fuel Flowmeter is an RF carrier type flowmeter.
(3) Set the CEC 2700 oscillator at the following points and record the indication on the calculating
counter and AEDATS:
Table 27-1 Oscillator Settings for T63 Fuel Flow (lb/hr) Alignment
Target Flowmeter Hz
Flowmeter
Calculating Cntr.
Calc.
AEDATS WFi PPH
AEDATS
Freq. from table 21-
PPH
Limits
Counter
Limits
WF
(Hz)
1
from table 21-
(calculated as
Reading (calculated as follows) Reading
1
follows)
Flowmeter PPH
Flowmeter PPH
0.35%
0.5%
600
800
1000
1200
1400
Note: Calculating Counter Reading = Oscillator Frequency x C, where C is calculated in paragraph 21