ARMY TM 9-1290-262-24&P
MARINE CORPS TM 00476C-24&P
AIR FORCE TO 49A7-3-72/74
3-3. ELBOW TELESCOPE--MAINTENANCE INSTRUCTIONS. (cont)
REASSEMBLY
If removed, drive in two pins (1) until they
1
extend 0.060 0.010 in. (1.524 0.254
mm) beyond the far surface.
If removed, drive in pin (2) until it is flush
2
with outer surface.
Install level vial (3) so that slot engages
3
the pin (2).
4
Loosely install eccentric (4) and eccentric
ring (5).
5
Snap level vial cover (6) in place and in-
stall two new self-sealing screws (7).
NOTE
tightened and sealed after elbow
telescope assembly is assembled to
the aiming circle and all adjustments
performed. Purge and charge. Refer
to TM 750-116.
3-4. AIMING CIRCLE PLATE BASE-MAINTENANCE INSTRUCTIONS
This task covers:
a.
Disassembly
c. Repair
b. Cleaning
d. Reassembly
INITIAL SETUP
Tools and Special Tools
Electronic system maintenance tool kit (SC 5180-95-CL-B29)
Materials/Parts
Gasket (8211732)
Synthetic rubber adhesive (item 1, appx D)
References
TM 9-254