TM 5-6675-331-14&P
Table 3-1. OPERATOR TROUBLESHOOTING - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3-8. NO POWER TO ROADSIDE OR CURBSIDE RECEPTACLES.
WARNING
Use extreme caution when performing checks or maintenance at or near power distribution box. Failure to
do so may result in death or serious injury.
Step 1. Check that ROADSIDE POWER CIRCUIT BREAKER is on.
Reset circuit breaker to on.
Step 2. Check that CURBSIDE POWER CIRCUIT BREAKER is on.
Reset circuit breaker to on.
Call Unit Maintenance if malfunction persists.
3-9. NO POWER TO ECU.
Check that ECU CIRCUIT BREAKER is on.
Reset circuit breaker to on.
Call Unit Maintenance if malfunction persists.
3-10. NO TENT LIGHTS.
Step 1. Check that cable is properly connected at DDSS tent power feed through connector. Reconnect cable
connector.
Step 2. Check that SICPS LIGHTS CIRCUIT BREAKER is on. Reset circuit breaker to on.
Call Unit Maintenance if malfunction persists.
3-4