TM 5-6675-331-14&P
Table 3-1. OPERATOR TROUBLESHOOTING - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3-11. NO POWER TO TENT EQUIPMENT.
WARNING
HIGH VOLTAGE
Use extreme caution when performing checks or maintenance at or near power distribution box. Failure to
do so may result in death or serious injury.
Step 1. Check that tent power cables are properly connected at DDSS power entrance box.
Reconnect cable connectors.
Step 2. Check that TENT POWER CIRCUIT BREAKERS are on.
Reset tent circuit breakers to on.
Call Unit Maintenance if malfunction persists.
Refer to TM 10-8340-225-10 Troubleshooting.
3-5