TM 5-6675-331-14&P
Table 4-2. UNIT TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4-13. INCANDESCENT LIGHTS DO NOT WORK.
Test incandescent light switch for continuity.
Replace incandescent light switch. (Refer to paragraph 4-25).
4-14. EMERGENCY LIGHTS DO NOT WORK.
Step 1. Check battery red charge indicator light. Full charge indicated by pulsating red light.
Replace batteries. (Refer to paragraph 4-29).
Step 2. If light still does not operate, replace emergency light. (Refer to paragraph 4-29).
4-15. NO POWER TO ROADSIDE OR CURBSIDE AUXILIARY RECEPTACLES.
WARNING
Use extreme caution when performing checks or maintenance at or near power distribution box.
Failure to do so may result in death or serious injury.
Check voltage at receptacle with multimeter.
If 120v does not exist, check circuit breaker for continuity.
If continuity exists, replace receptacle (refer to paragraph 4-26).
If no continuity at circuit breaker, replace circuit breaker (refer to paragraph 4-24).
4-9