TM 5-6675-328-14
Table 7-5. DIRECT/GENERAL SUPPORT TROUBLESHOOTING PROCEDURES - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3.
BATTERY CHARGER OPERATES BUT TIMER WILL NOT MOVE FROM SELECTED POSITION. Check for
defective TIMER.
Replace TIMER (paragraph 7-20.3).
4.
BATTERY..CHARGER WILL NOT OPERATE IN ONE OR MORE POSITIONS OF THE CHARGING RATE
SWITCH.
Step 1. Check for defective CHARGING RATE switch.
(a)
Replace CHARGING RATE switch (paragraph 7-20.2).
(b)
If battery charger still does not operate, replace battery charger.
7-20.
MAINTENANCE PROCEDURES.
a.
This section contains instructions covering direct/general support maintenance functions for the battery charger.
Personnel are listed only if the task requires more than one.
b.
After completing each maintenance procedure, perform operational check to be sure that equipment is properly
functioning.
INDEX
PROCEDURE
PARAGRAPH
Replace AMMETER OR VOLTMETER. ........................................................................................
7-20.1
Replace CHARGING RATE Switch ...............................................................................................
7-20.2
Replace TIMER ............................................................................................................................
7-20.3
Replace Circuit Breaker ................................................................................................................
7-20.4
Replace Diode .............................................................................................................................
7-20.5
7-19