TM 5-6675-325-14
4-16.2 Replace Switch (es).
MOS: 41B, Topographic Instrument Repair Specialist
TOOLS: 3/32 in. Hex Head Key Wrench
Soldering Iron
SUPPLIES: Switch
Solder (Item 23, Appendix E)
Wire Ties
WARNING
Death or serious injury may occur from electrical shock unless power cord
is unplugged before servicing.
a.
Unplug power cord.
b. Remove socket head screws and control panel.
NOTE
Tag all electrical connections before removing to be sure of proper
reassembly.
4-29