TM 5-6675-325-14
Table 4-3. ORGANIZATIONAL TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4.
INVERTER ASSEMBLY WILL NOT REDUCE OR ENLARGE IMAGE.
Step 1.
Check for defective RATIO switch.
(a) If switch is not defective, proceed to step 2.
(b) Replace defective RATIO switch (paragraph 4-16.2).
Step 2.
Check for defective magnification drive motor.
Replace defective magnification drive motor (paragraph 4-16.6).
5.
COPY EASEL WILL NOT TILT TO RECTIFY IMAGE.
Step 1.
Check for defective drive chain.
(a) If chain is not defective, proceed to step 2.
(b) Replace drive chain (paragraph 4-16.7).
Step 2.
Check for defective rectifying tilt motor.
(a) If tilt motor is not defective, proceed to step 3.
(b) Replace defective rectifying tilt motor (paragraph 4-16.5).
Step 3.
Check for defective tilt switch.
Replace defective tilt switch (paragraph 4-16.2).
4-16. MAINTENANCE PROCEDURES.
This section contains instructions covering organizational maintenance
functions for the vertical reflecting projector.
Personnel required are listed only
if the task requires more than one.
b. After completing each maintenance procedure, perform operational check to be
sure that equipment is properly functioning.
a .
4-26