TM 5-6675-325-14
WARNING
Death or serious injury may occur from electrical shock unless power cord
is unplugged before servicing.
b. Turn off power switch and unplug power cord.
NOTE
Tag all electrical connections before removing to be sure of proper
reassembly.
c.
d.
e.
f.
g.
h.
i .
j.
Remove screws retaining electrical wiring to limit switch. Tag and
remove wires.
Remove bolts, nuts, and washers retaining limit switch to copy easel.
Remove defective limit switch from copy easel.
Install new limit switch on copy easel.
Reinstall washers, nuts, and bolts retaining limit switch to copy
easel and tighten bolts securely.
Reconnect electrical wiring in proper order to limit switch.
Reinstall screws retaining wiring to limit switch and tighten
screws securely.
Plug in power cord.
4-31