TM 5-6675-324-14
NOTE
Calculator will print horizontal and true slope surface area of shape
last measured, followed by totals (added or subtracted) of horizontal
and true slope surface areas.
(6) Keeping foot switch depressed, reposition planimeter near shape to be
measured.
(7) Make next measurement.
(8) If change is made in planimeter function or if new seal es or Slope ratios
to initiate measurement. Begin measurement procedures.
are used, press
Measuring areas without the calculator.
s.
(1) Assemble QPS with planimeter.
(2) Activate QPS:
(a) Plug foot switch into ACCU input jack on back panel of auto-scaler.
(b) Plug Planimeter into E2 encoder socket on back panel of auto-sealer.
(c) Plug power transformer cable into POWER supply jack on back panel of
auto-scaler.
(e) Plug power cord into back of calcalator.
(f) Plug power cord into wall outlet.
(9) set encoder OFF/E2/El switch on back of auto-scaler to E2.
(h) Set AUDIO/OFF switch on back panel of auto-sealer to AUDIO.
(i) Set auto-scaler B/ACCU/A/OFF switch to A.
(j) Set auto-scaler MAN/AUTO switch to MAN.
(k) Set auto-scaler X MEMORY switch to 1.
(1) Set calculator OFF/ON switch to OFF.
(3) Tape map or drawing to be measured to table.
(4) Select correct tracer arm length.
(5) If needed, aline planimeter for tracer arm length selected (paragraph
5-61