TM 5-6675-323-14
1. Alinement of planimeter with lens tracing assembly. Alinement of the
p l a n i m e t e r provides information needed to make area and volume measurements. Using
the testing procedure provides values needed to check alinement with factory
determined values and provides a constant in determining additional measurements and
calculations.
T e s t measurement is made with the test rule. Measurement with the
test rule traces a circle with a two inch radius. The area of that circle has a
f a c t o r y d e t e r m i n e d a r e a AT , f o u n d o n t h e C a l i b r a t i o n R e c o r d s S h e e t p r o v i d e d w i t h
t h e equipment.
(1) Assemble QPS using the planimeter with lens tracing assembly.
(2) Activate QPS:
(a) Plug foot switch into CLEAR input jack on back panel of auto-scaler.
( b ) Plug remote tracer switch into ACCU input jack on back panel of auto-
scaler.
( c ) P l u g p l a n i m e t e r i n t o E1 , e n c o d e r s o c k e t o n b a c k p a n e l o f a u t o - s c a l e r .
auto-scaler.
(f) Plug power cord into back of c a l c u l a t o r .
(g) plug power cord into wall outlet.
( h ) S e t e n c o d e r 0 F F / E2 / E1 s w i t c h o n b a c k p a n e l o f a u t o s c a l e r t o E1 .
(l) Set AUDIO/OFF switch on back panel of auto-scaler to AUDIO.
(j) Set auto-scaler B/ACCU/A/OFF switch to A.
( k ) Set auto-scaler MAN/AUTO switch to AUTO.
(l) Set auto-scaler X-memory switch to 1.
( m ) Set calculator OFF/ON switch to ON.
( n ) Set calculator MAN/TRACE/NORM switch to NORM.
(o) Set calculator PRGM/RUN switch to RUN.
,
,
,
and
.
(p)
Press
following
keys:
(3) Remove Y-shaped test rule from carrying case.
(4) Tape piece of paper to table.
(5) Draw a horizontal line 12 inches long.
(6) Place planimeter on paper so it straddles line drawn.
9-50