TM 5-6675-323-14
Table 3-24. DIRECT/GENERAL SUPPORT TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3.
NO PEN MOVEMENT IN "X" DIRECTION.
Step 1.
O p e n plotter.
Check position of X-axis mute switch S1 on PCA A2.
(a) If S1 is off, proceed to step 2.
(b) Turn off mute switch S1.
S t e p 2.
(a) If either is defective, replace fuse and turn S1 on.
(b)
( c ) If problem persists, replace X-drive motor (paragraph
3-29.14).
3-232