TM 5-6675-323-14
Table 3-20. PLOTTER PROGRAMMING LANGUAGE - Cont
S t a t e m e n t Identification and Use
Program
Statement
S t a t e m e n t , Syntax, Explanation, and Input Instructions
w r t 705, "AP"
w r t - Cont
Automatic pen pickup command, " A P " , causes plotter to auto-
m a t i c a l l y raise pen whenever it has been down without motion
for 65 seconds. This condition is set automatically when
plotter is initialized.
S e n d i n g c h a r a c t e r s " A P O " to plotter will disable automatic pen
pickup.
w r t 705, "PD"
Pen down command, PD, lowers pen to paper.
w r t 7 0 5 , ` V S 1 thru 36 [, Pen No.]n
Select pen velocity command specifies pen speed, in cm/sec,
for plotting and lettering operations. Velocity can be any
v a l u e between 1 and 36.
If optional pen no. (1-8) is speci-
fied, speed will apply only to that pen. If pen no. is not
specified, speed applies to all pens.
Whenever plotter is initialized, pen velocity is set to 36
cm/sec.
w r t 705, `VA"
Sets plotter to adaptive pen velocity mode. Plotter will
adapt pen speed, automatically, to approximate rate that com-
puter sends coordinate data to plotter. This mode provides
smoother plot than normal velocity mode for plotting coordi-
nates that are generated by a relatively slow program routine
w r t 705, `VN"
Normal velocity command, `VN", c a n c e l s a d a p t i v e v e l o c i t y m o d e .
Pen speed is now controlled by current pen velocity command.
3-203