TM 5-6675-323-14
Table 3-20. PLOTTER PROGRAMMING LANGUAGE - Cont
S t a t e m e n t Identification and Use
Program
Statement
S t a t e m e n t , Syntax, Explanation, and Input Instructions
w r t - Cont
w r t 7 0 5 , "CA (-4)"
Alternate character command specifies alternate character set
Set is automatically specified as alternate character set
whenever plotter is initialized.
w r t 705, "SS"
Standard set command selects standard set as character set to
be used for all labeling statements (lbl, ptyp, xax, and y a x ) .
Standard set is selected automatically when plotter is first
switched on, initialized, or cleared.
3-208