(11) To perform the front panel interactive tests, after completing self-
test:
( a ) Mute the X-motor at S1 on the main PCA A2, and move the plotter
arm to the left end of the platen (nearest pen stall #1). Turn
S1 on.
(b) Remove all pens from the front panel.
(c) Press the pen select pushbutton #8.
(d) The self-test LEDs will indicate 1011 and all front panel LEDs
will be on for a lamp test.
( e ) Press CONTINUE (green).
A l l front panel indicators except ERROR
will be off.
(f) Press the front panel switches in the order given on self-test
chart.
( g ) AS e a c h s w i t c h c l o s e s , the ERROR LED will go off and the OUT OF
L I M I T LED will turn on momentarily. Go to the next switch when
the ERROR LED comes on.
(h) Upon completion of the front panel test, the self-test LEDs will
flash sequentially.
(12) To perform the motor vector tests, proceed as follows:
(a)
Press CONTINUE (S3).
(b)
P r e s s pen select pushbutton #1. The plotter arm and pen holder
will begin a diagonal move. A l l s e l f - t e s t L E D s w i l l b e o f f . A n
error is indicated by failure of the plotter to make the move.
(c)
P r e s s and hold pen select pushbutton #2 until the arm movement
stops .
Release the pushbutton, and the plotter will begin the
second vector. Repeat with pen select pushbuttons 3 through 6.
Each button initiates a new vector.
(d)
U p o n completion of the vector test, set the SELF TEST switch S4-2
t o the off position, and press the RESET switch S5 pushbutton
(red). The plotter will complete a power-up initialization.
(e)
Turn off the plotter, remove the power cord, and close the plotter.
Secure the upper deck locking screws and replace the rear hood.
3-170