TM 5-6675-323-14
(1)
Remove p o w e r f r o m t h e p l o t t e r .
(2)
Remove a l l i n t e r f a c e c a b l e s .
(3)
Open the plotter.
(4)
Apply power to the plotter.
(5)
S e t the SELF TEST switch S4-2 to the on position.
(6)
P r e s s the RESET switch S5 pushbutton (red).
(7)
The self-test LEDs will flash sequentially as a lamp test.
(8)
P r e s s the CONTINUE switch S3 pushbutton (green).
(9)
The test will run to the end of the automatic tests or to a fault
indication.
T o continue after any error, press the CONTINUE push-
button S3 (green).
(10)
The self-test LEDs will flash in unison when the automatic tests are
complete or indicate the binary number of the failed step if one is
found.
3-169