TM 5-6675-320-14
c .
O p e r a t i o n t e s t ( f o u r c o l o r p l o t ) .
WARNING
Death or serious injury may occur from electrical shock. Plotter is
equipped with three-conductor power cable which grounds plotter. Do not
operate plotter from ac outlet that does not have connected ground pin.
CAUTION
Be sure power is off before plugging HP-IB Interface to equipment, or
damage
( 1)
(2)
( 3)
( 4)
( 5)
( 6)
( 7)
(8)
(9)
t o e q u i p m e n t w i l l r e s u l t.
Turn off (0) LINE power switch.
Check that voltage switches are set for 120 V ac.
Turn LISTEN ONLY switch to 0.
Turn CONFIDENCE TEST switch to I.
Set logic ADDRESS switches to 5 (10100).
Plug in power cable.
Press LINE power switch to ON.
I n i t i a l i z e p l o t t e r .
(a) Press ENTER key.
(b) Press CHART HOLD switch.
Mount paper.
(a) Press CHART LOAD switch.
(Pen should go to upper right corner).
(b) Raise paper stop by pressing down upper
other pointed object.
portion with screwdriver or
4-62