TM 5-6675-320-14
e. Press LINE power switch on
f o l l o w s :
( 1 ) P e n r a i s e s .
f r o n t b a s e o f p l o t t e r.
P l o t t e r s h o u l d r e s p o n d a s _
(2) Pen moves to lower right corner of platen.
4 - 6 . 2 I n i t i a l A d j u s t m e n t s , D a i l y C h e c k s . and Self-Test.
a .
Perform the operation confidence test as follows:
(1) Turn LINE power switch to off (0).
(2)
( 3)
( 4)
( 5)
(6)
( 7)
(8)
( 9)
(10)
Check that power cables are connected and voltage switches are set
for 120 V ac operation.
Check that HP-IB interface is not connected.
Turn LISTEN ONLY switch to 0.
Turn CONFIDENCE TEST switch to 0.
Check that logic ADDRESS switches are set to 1Ø1ØØ.
I n i t i a l i z e p l o t t e r :
(a) Press LINE power switch.
(b) Press ENTER key.
(c) Press CHART HOLD switch.
Mount paper.
Install pen in pen arm.
Turn CONFIDENCE TEST switch to 1.
After completion
should stop in lower left corner of platen, and all
panel should be turned on.
o f p l o t , p en
lamps on front
4-58