TM 5-6675-319-14
NOTE
After installation of high-voltage box assembly, perform +10 kV adjustment,
(paragraph 9-20.22) accelerator anode calibration adjust R120, (paragrap h
9-20.26) beam current adjust R23, (paragraph 9-20.22) and electronic
CRT spot adjust (paragraph 9-20.27).
l .
Close operators console and lower cabinet door.
m.
Turn on circuit breaker.
n.
Turn on MASTER POWER switch.
9-20.10
Replace Choke L102.
MOS:
35E, Special Electronic Devices Repairer
TOOLS :
Flat Tip Screwdriver
Solder/Desolder Set
1/4 in. Socket Set
SUPPLIES: Choke
Solder (Item 30, Appendix E)
WARNING
Death or serious injury may occur from electrical shock unless power is
t u r n e d o f f b e f o r e s e r v i c i n g .
CAUTION
Never have printer hood down with power on and normal room lights on.
This condition will damage PMT.
a.
Turn off MASTER POWER switch.
b . T u r n o f f c i r c u i t b r e a k e r .
c .
Open operators console.
9-150