TM 5-6675-319-14
9-20.11 Replace PMT Digital Meter M101.
MOS: 35E, Special Electronic Devices Repairer
TOOLS: None
SUPPLIES: Digital Meter
Death or serious injury may occur from electrical. shock unless power is
t u r n e d o f f b e f o r e s e r v i c i n g.
CAUTION
Never have printer hood down with power on and normal room lights on.
This condition will damage PMT.
a.
Turn off MASTER POWER switch.
b.
T u r n o f f c i r c u i t b r e a k e r.
c .
Open operators console.
d. Disconnect PMT meter connector.
e.
Remove PMT digital meter. Squeeze tabs and push meter upward.
f . R e p l a c e d e f e c t i v e P M T d i g i t a l m e t e r . T a b s w i l l l o c k m e t e r i n p l a c e.
g .
Reconnect PMT meter connector.
h . Close operators console and lock.
i .
Turn on circuit breaker.
j. Turn on MASTER POWER switch.
9-152