Loosen one side of retaining spring by removing screw and nut.
j .
R e m o v e s c r e w s , f l a t w a s h e r s , l o c k w a s h e r s , a n d n u t s f r o m y o k e b r a c k e t s .
NOTE
Tag yoke brackets and CRT frame to ensure proper reinstallation.
k. Turn yoke assembly half right and carefully lift from CRT.
l. Mark position of CRT anode with respect to shelf assembly to ensure
p r o p e r r e i n s t a l l a t i o n .
m.
Remove CRT frame by removing screws, self-locking washers and nuts.
n.
Replace defective CRT.
9-146