Drain system by opening DEV, FIX, and WASH drain valves, and rotating
sump pump directional flow valve to DRAIN position.
d. Close all drain valves and fill wash tank with water.
e.
Clean and drain wash tank. Close WASH drain valve.
f. Remove developer filter element (paragraph 2-10.3) .
CAUTION
Use developer cleaner only in developer tank and fixer cleaner only in
f i x e r t a n k . F o l l o w m a n u f a c t u r e r s i n s t r u c t i o n s f o r c l e a n e r m i x i n g r a t i o s.
Use splash guards when servicing processor or serious contamination of
u n i t w i l l r e s u l t.
g.
Fill developer tank with developer system cleaner .
h.
F i l l f i x e r t a n k w i t h f i x e r s y s t e m c l e a n e r .
CAUTION
Do not immerse racks in cleaning solutions longer than 15 minutes or
damage may result.
2-59