Table 2-2. TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4.
RECYCLED WASH WATER DOES NOT ENTER PROCESSOR - Cont
Step 2.
Check that the recycling directional flow valve is in pump position.
(a) If in pump position, proceed to step 3.
( b ) I f n o t i n p u m p p o s i t i o n , r o t a t e r e c y c l i n g d i r e c t i o n a l f l o w
valve to pump position.
Step 3.
Check for clogged recycling hoses.
(a) If hoses are clogged, clean hoses.
( b ) I f h o s e s a r e n o t c l o g g e d , r e p l a c e r e c y c l i n g f i l t e r ( p a r a g r a ph
2-10.6).
5.
CHILLER DOES NOT OPERATE WHEN MAIN POWER SWITCH IS ON.
Check for unplugged power supply cord.
(a) If unplugged, plug power supply cord in.
(b) If malfunction persists, refer to organizational maintenance.
6.
WITH MAIN POWER SWITCH ON, HEATING ELEMENTS WILL NOT MAINTAIN PRESET
TEMPERATURE IN TANKS.
Check for HEATER switch in OFF position.
(a) If switch is off, turn on HEATER switch.
(b) If malfunction persists, refer to organizational maintenance.