TM 5-6675-319-14
i .
j .
k .
l .
m.
n.
o .
p .
q .
r .
s.
Turn on PUMP and DRIVE switches on front panel, and run unit for
approximately 15 minutes.
Drain system by opening DEV and FIX drain valves. Close valves after
d r a i n i n g .
Remove and clean wash, fixer, and developer rack assemblies.
Fill wash, developer, and fixer tanks with clean water.
Turn PUMP and DRIVE switches on, and run unit for 5 minutes; then turn
o f f b o t h s w i t c h e s.
Open DEV, FIX, and WASH drain valves, and drain system. Close valves.
Reinstall wash, fixer, and developer rack assemblies.
R e f i l l t a n k s w i t h c l e a n w a t e r.
Turn PUMP and DRIVE switches on, and run unit for 10 minutes; then turn
o f f b o t h s w i t c h e s.
Open DEV, FIX, and WASH drain valves, and drain system. Close all
valves and rotate the sump pump directional flow valve to RECYCLE posi-
tion.
Install new developer filter element (paragraph 2-10.3).
CAUTION
Use splash guard when filling developer and fixer tanks to prevent conta-
m i n a t i o n o f s o l u t i o n s.
t .
Refill tanks with fresh developer and fixer solutions (paragraph 2-6.1).
2 - 1 0 . 3 R e p l a c e D e v e l o p e r F i l t e r.
MOS:
83E, Photo and Layout Specialist
SUPPLIES:
F i l t e r C a r t r i d g e
Gasket
WARNING
Death or serious injury may occur from electrical shock unless power i s
t u r n e d o f f b e f o r e s e r v i c i n g.
a.
Turn off all processor power switches and RECYCLING PUMP switch.
2-60