TM 5-6675-315-14
Table 2-6. DIRECT/GENERAL SUPPORT TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5.
CYCLE STOP (KLP) DOES NOT LIGHT WHEN CHAMBER IS FULL. RAM DOES NOT RETURN.
Step 1. Check for sticking solenoid valve.
(a)
If valve is operating properly, proceed to step 2.
(b)
If sticking, replace valve (paragraph 2-20.4).
Step 2. Check pressure activated switch DW for proper adjustment.
(a)
If properly adjusted, proceed to step 3.
(b)
If out of adjustment, replace switch DW (paragraph 2-20.5).
6.
BALE CHAMBER IS PARTIALLY FULL. RAM DOES NOT REVERSE.
Step 1. Check for sticking solenoid valve.
(a)
If valve is operating freely, proceed to step 2.
(b)
If sticking, replace valve (paragraph 2-20.4).
Step 2. Check for defective solenoid valve.
Replace valve (paragraph 2-20.4).
2-135