TM 5-6675-250-20
2 - 9 . P M C S ( C o n t i n u e d)
Table 2-2. Organizational Preventive Maintenance
B - Before Operation
Checks and Services
L E G E ND
A - After Operation
I t em
N o .
I n t e r v al
1
2
3
4
B
l
l
l
l
A
l
l
l
l
Item to be
I n s p e c t ed
T r a n s p o rt
c a s e
A c c e s s o r i es
C a b le
a c c e s s o r i es
A C - D C
c o n v e r t er
P r o c e d u re
Inspect for inoperable
handles, latches or
m o u n t i n g . I n s p e ct
case interior for con-
dition of isolators,
bumpers, seals, latch
supports and struc-
ture. Inspect for
inoperable relief
valve. Replace an
inoperable relief
valve.
Replace damaged or
m i s s i n g a c c e s s o r i es
with serviceable equip-
m e n t .
Inspect for severed
cable, cracked or
o t h e r w i s e d a m a g ed
connectors, and bent
or broken pins.
Ensure that protective
caps are installed on electrical
c o n n e c t o r s . R e p o r t d a m a g ed
c a b l e a s s e m b l i e s t o D i r e ct
S u p p o r t M a i n t e n a n c e.
Inspect electrical
connectors for loose
mounting and check
to see if protective
caps are installed.
Check to see that
cover is securely in-
stalled. Report any
damage to Direct Sup-
p o r t M a i n t e n a n c e.
Equipment Is Not
R e a d y / A v a i l a b le
I f :
Handles or latches are
inoperable. Relief
valve is defective or
i n t e r i o r c o m p o n e n ts
are damaged or mis-
sing or case is
d a m a g e d .
C o m p o n e n t s a re
damaged or mis-
s i n g.
Cables or con-
nectors are
damaged or de-
fective. Caps
are damaged or
m i s s i n g.
E l e c t r i c a l c o n n e c t o rs
are damaged or
protective caps are
missing or damaged.
Converter is otherwise
damaged in any way.
2-16