TM 5-3610-287-24
REPAIR EXPANDING SIDE ASSEMBLY (CONT)
3-17.
WARNING
Stay clear as folding floors are raised or lowered. Weight
of floors may cause serious injury.
1.
Raise folding floor and lock in up position (TM 5-3610-287-10,
2.
Remove seal (1) from track (2).
CAUTION
Do not cut excess length from seal. Excess length will be
drawn into track after seal is inserted. Cutting seal will
cause improper fit.
3.
Position new seal (1) on track (2) and insert base of seal into
track (2).
4.
Lower folding floor and lock in down position (TM 5-3610-287-10,
3-26