TM 5-3610-287-24
REPAIR PERSONNEL/EQUIPMENT DOOR (CONT)
3-16.
1.
Open and secure door (1).
Remove screw nails (2) from seal (3).
2.
Remove corner reinforcement seals (4) from seals (3) at each corner of
3.
door (1).
4.
Remove corner tab seals (5).
Remove seals (3) from door (1) and scrape remaining pieces of seal (3)
5.
and adhesive.
WARNING
CHEMICAL HAZARD. Use rubber cement thinner in a well-
ventilated area. Failure to do so may result in damage to
respiratory system. Wear gloves and goggles to prevent
injuries to skin and eyes.
Wipe surface dry.
Remove remaining adhesive with rubber cement thinner.
6.
3-21