TM 5-3610-287-24
2-44.
REPAIR WATER TANK ASSEMBLY (CONT)
8.
Install grommet (5) on thermometer cable (6).
9.
Run thermometer cable (6) through hole in sink top.
10.
Install grommet (5) in sink top.
11.
Install cable clamps (4) with screws (3).
WARNING
CHEMICAL HAZARD. Use silicone compound in a well-ventilated
area. Silicone compound is harmful to eyes and skin. In
case of contact with eyes, immediately flush eyes with water
for 15 minutes, then seek medical help. In case of contact
with skin, wipe off with dry cloth, then wash with soap and
water.
12.
Slide B-nut (1) and ferrule (9) on probe (2). Apply silicone compound
to ferrule.
CAUTION
Excessive pressure from ferrule
Do not overtighten B-nut.
will damage probe.
13.
Install probe (2) in water tank and tighten B-nut (1).
14.
To test operate, fill water tank (TM 5-3610-287-10, para 2-6).
WATER TANK
INITIAL SETUP
Tools
Shop equipment common no. 1 tool kit (appendix B, section III, item 12)
Cross-tip screwdriver
Socket wrench set
Pipe wrench
Adjustable wrench
Flat-tip screwdriver
Materials/Parts
Water tank, 13226E7901
2-121