TM 5-3610-287-24
REPAIR WATER TANK ASSEMBLY (CONT)
2-44.
1. Remove plastic nut (1) and plastic sight gage (2).
2.
Remove liquid level gage (3) by loosening hex nut (4).
NOTE
Ensure cork arm is facing heater end of water tank when
installed.
3.
Mark position of cork arm (5) on face of hex nut (4) on new liquid
level gage (3).
4. Apply PTFE tape to pipe threads and install liquid level gage (3) with
hex nut (4). Ensure mark on hex nut points toward heater end of tank.
5.
Install plastic sight gage (2) and plastic nut (l).
6.
To test operate, fill water tank (TM 5-3610-287-10, para 2-6) and
observe gage for proper operation.
2-118