TM 5-3610-287-24
2-44.
REPAIR WATER TANK ASSEMBLY (CONT)
Remove knob (8).
Loosen screws (9) and remove cover (10).
5.
Tag and remove wiring (11).
6.
7.
Remove segmented locknut (12) and pull strain relief (13) from
immersion heater (6).
Remove gasket (14) and coupling flange (15).
8.
Apply PTFE tape to pipe threads on new immersion heater. Install
9.
coupling flange (15) and gasket (14) on new immersion heater (6).
10.
Install strain relief (13) with segmented locknut (12).
11.
Connect wiring (11).
12.
Install cover (10) and tighten screws (9).
13.
Install knob (8).
Install immersion heater (6) in water tank (7) with hex bolts (5).
14.
Install wall plate (2) with screws (1).
15.
To test operate, fill water tank (TM 5-3610-287-10, para 2-6). Set
16.
knob (4) to desired temperature. Observe until thermometer
stabilizes. Check for leaks.
Install cover plate (4) with screws (3).
17.
LIQUID LEVEL GAGE
INITIAL SETUP
Tools
Shop equipment common no. 1 tool kit (appendix B, section III, item 12)
Pipe wrench
Materials/Parts
Liquid level gage, 13227E6257
Personnel Required
Utilities Equipment Repairer 52C10
2-117