TM 5-3610-287-24
2-43.
REPLACE MAIN PUMP (CONT)
Connect wires (4) with wire nuts (5).
11.
12.
Install cover plate (3) with screws (1).
13.
Set WATER HEATER AND PUMP circuit breaker to ON.
14.
To test operate pump, fill water tank (TM 5-3610-287-10, para 2-6) and
check for leaks.
Water tank assembly is repaired by replacing: a. Immersion heater
b. Liquid level gage c. Remote reading thermometer d. Water tank
IMMERSION HEATER
INITIAL SETUP
Tools
Shop equipment common no. 1 tool kit (appendix B, section III, item 12)
Flat-tip screwdriver
Combination wrench set
Socket wrench set
Materials/Parts
Immersion heater, 13227E6258
Gasket, 13226E7973
Personnel Required
Utilities Equipment Repairer 52C10
Equipment Conditions
Water tank drained (TM 5-3610-287-10, para 2-7)
2-115