3-5.
DAMPENING ROLLERS MAINTENANCE INSTRUCTIONS (CONT)
REMOVAL
1.
Remove dampening fountain roller no. 24.
a.
b.
roller
c.
Disengage safety catch.
Using dampening fountain roller ratchet , rotate dampening fountain
no. 24 until half coupling on roller shaft (operator side) faces up.
CAUTION
Use roller supports for removed
stored in roller rack. Failure
roller surface.
rollers that are not
to do so may damage
Push roller to drive side and lift out of Printing Press.
2.
Remove dampening ductor roller no. 23.
a. Loosen locknut and turn knurled adjustment screw to left to loosen
roller latch.
in
3.
20
b.
Remove dampening ductor roller no. 23 from Printing Press and store
roller rack.
Remove dampening form rollers no. 20 and no. 21.
a. Using T-handle socket wrench, disengage dampening form rollers no.
and no. 21 from plate.
b.
Pull rollers toward operator side of Printing Press and remove.
c. Store rollers in roller rack.
REPAIR
CAUTION
Extreme care must be used when cutting old roller cover away
from roller. Cutting into roller surface will damage
equipment.
NOTE
The following steps are the same for both dampening form
rollers no. 20 and no. 21 and dampening ductor roller no. 23.
1.
Using razor blade, carefully cut old cover from roller.
3-21