e. Remove plastic hose connector from vacuum swivel body.
f. Remove vacuum hoses from tee connector on vacuum swivel body.
g. Remove tee connector on vacuum swivel body.
h. Loosen two nylon screws on vacuum swivel body and remove vacuum swivel body.
i. Remove nut and vacuum swivel shaft.
j. Remove two mounting nuts from vacuum gage and remove defective vacuum gage through top of
control box.
k. Install new vacuum gage through top of control box, place mounting bracket around gage so that
mounting studs fit through the holes. Then attach in place with mounting nuts. Be sure gage is
properly centered on panel.
l. Reinstall vacuum swivel shaft and nut on bottom of vacuum gage.
m. Reinstall vacuum swivel body on vacuum swivel shaft and tighten two nylon screws.
n. Reinstall tee connector on vacuum swivel body.
o. Reinstall vacuum hoses on tee connector.
p.
Reinstall plastic hose connector on vacuum swivel body.
q.
Reconnect vacuum frame vacuum hose on control box.
r.
Reinstall vacuum control box on frame.
s.
Reinstall cover plate on underside of vacuum control box.
t. Plug in power cord for vacuum control box.
6-46